EVI Air water heat pump

EVI Air water heat pump

Model No.︰CAR-20/24EVI

Brand Name︰CliTech

Country of Origin︰China

Unit Price︰-

Minimum Order︰2 pc

Inquire Now

Product Description

EVI Air Source Heat Pump For Low Temp -25degree is specially designed for cold climate area, can best satisfy the household and commercial of sanitary hot water and floor heating use, it can work down to low temp of -25C.

Applicable place: for cold climate area family houses, villas, hospitals, hotels, staff dormitory and so on.
Super high efficiency: EVI Copeland compressor is uses, as standard working mode, COP higher of 4.0
Super low temp heating: EVI Copeland compressor is adopted, can work down to -25C, assured of low temp running heating.
Intelligent defrosting technology: Evaporator of finned tube heat exchanger is designed for big air flow, and its wave shape finned tube design efficiently reduced get frosting in winter. To the climate of dry air, adopted “time + temp difference” defrosting control technology, assured defrosting of in time and clean.

Parameter list:

Model

 

CAR-20EVI

CAR-24EVI

Standard

Heating capacity

KW

20.3

20.8

BTU

69264

70969

Hot water output

T/h

0.44

0.45

Input power

KW

4.8

5.12

Low

Heating capacity

KW

16.6

17.3

BTU

56639

59028

Hot water output

T/h

0.32

0.33

Input power

KW

4.69

5.2

Super low

Heating capacity

KW

9.7

10.66

BTU

33096

36372

Hot water output

T/h

0.19

0.2

Input power

KW

4.15

5

Standard running current

A

8.4

24.4

Max running current

A

12

34.2

Power source

V/Ph/Hz

380V/3N/50HZ

Noise level

dB(A)

58

58

Up discharge W x D x H

mm

810*780*1050

1390*635*950

Side discharge W x D x H

mm

1120*425*1260

900*420*1400

Net weight

kg

145

175

Water temp control precise

°C

±2°C

Working ambient temp range

°C

-25°C-43°C

Throttle type

 

Thermostatic expansion valve

Refrigerant

Type

 

R407C

Charge qty

kg

3.5

2.6*2

Max working pressure

Bar

28

28

Compressor

Type

 

Hermetically sealed scroll compressor

Qty

pcs

1

2

Blocking current

A

60

60

Air source side

Heat exchanger type

 

Finned tube heat exchanger

Heat exchanger qty

pcs

1

2

Motor power

KW

0.4

0.4

Hot water side

Heat exchanger type

 

Tube in tube heat exchanger

Water flow

m3/H

3.49

3.58

Water pressure down

kPa

30

30

pipe size

DN

25

25

Max working pressure

kPa

1000

1000

Test conditions:
1.Standard:  Air source side DB/WB is 20C/15C, inlet water temp 15C, outlet water temp 55C.
2.Low:  Air source side DB/WB is 7C/6C, inlet water temp 10C, outlet water temp 55C. 
    
3.Super low: Air source side DB/WB is -15C/-17C, inlet water temp 10C, outlet water temp 55C.          

Price Terms︰ FOB Guangzhou or CIF client's port

Payment Terms︰ 30% TT as deposit, balance before shipment

Packing︰ Export standard plywood casing

Lead Time︰ 10-20 days after deposit confirmation

Standards Certificate︰ CE, CCC, ISO 9001/2000

Transportation︰ By sea or by air shipment

Shipping time︰ 30 days(by sea) or 5 days(by ship)

Product casing︰ galvanized metal sheet or stainless steel sheet

Discharge way︰ Up discharge or side discharge

Product Image