Model No.︰CAR-18
Brand Name︰CliTech
Country of Origin︰China
Unit Price︰-
Minimum Order︰1 pc
Website:www.clitechchina.com
Word: High COP DC Inverter Air To Water Heat Pump
MODEL |
|
CAR-11 |
CAR-18 |
|
Rated heating capacity |
KW |
10.8 |
18.5 |
|
BTU |
36850 |
63122 |
||
Hot water supply |
T/h |
0.23 |
0.4 |
|
Heating input power |
KW |
2.38 |
4.05 |
|
Rated heating input current |
A |
12.23 |
7.2 |
|
Max rating current |
A |
13 |
12 |
|
COP |
|
4.53 |
4.57 |
|
Power Supply |
V/Hz |
220V/1Ph/50Hz |
380V/3Ph/50Hz |
|
Noise level |
dB(A) |
<50 |
<55 |
|
Working temperature range |
°C |
﹣20°C~43°C |
||
Output water temperature |
°C |
60°C |
||
Unit size W x D x H |
mm |
1115 * 425 *710 |
900 *530 *1100 |
|
Unit net weight |
KG |
81 |
160 |
|
Throttle type |
|
Electronic expansion valves |
||
Refrigerant type |
|
R410A |
||
Compressor |
Type |
|
DC inverter rotary |
|
Quantity |
pcs |
1 |
1 |
|
Air source side |
Heat exchanger type |
|
Finned heat exchange |
|
Quantity |
pcs |
1 |
2 |
|
Fan type |
|
Axial big twist Angle fan |
||
Motor power |
KW |
0.09 |
0.25 |
|
Hot water side |
Heat exchanger type |
|
Efficient tube in tube heat exchanger |
|
Water flow |
m3/H |
1.85 |
3.09 |
|
Water pressure loss |
kPa |
20 |
25 |
|
pipe size |
DN |
20 |
25 |
|
water side max working pressure |
kPa |
1000 |
1000
|
Test condition: Air source side DB/WB is 20C/15C, initial water temp 15C, outlet water temp 55C.
Price Terms︰ 30% TT as deposit, balance before shipment
Payment Terms︰ FOB Guangzhou or CIF client's port
Packing︰ Export standard plywood casing
Lead Time︰ 20-25 days after deposit confirmation
Standards Certificate︰ CE, CCC, ISO 9001/2000
Transportation︰ By sea or by air shipment
Shipping time︰ 30 days(by sea) or 5 days(by air)
Product casing︰ galvanized metal sheet or stainless steel sheet
Discharge way︰ side discharge